Current Methods for Assessing Osseointegration of Nanostructured Titanium Implants

Authors

  • A. Moztarzadeh Department of Medical Chemistry and Biochemistry, Faculty of Medicine in Pilsen, Charles University, Pilsen
  • O. Moztarzadeh Department of Stomatology, Faculty of Medicine in Pilsen, University Hospital and Charles University, Pilsen | Department of Anatomy, Faculty of Medicine in Pilsen, Charles University, Pilsen
  • T. Kubíková Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen
  • Z. Tonar Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen
  • D. Hrušák Department of Stomatology, Faculty of Medicine in Pilsen, University Hospital and Charles University, Pilsen
  • A. Zicha Department of Stomatology, Faculty of Medicine in Pilsen, University Hospital and Charles University, Pilsen
  • V. Babuška Department of Medical Chemistry and Biochemistry, Faculty of Medicine in Pilsen, Charles University, Pilsen

Keywords:

osseointegration, dental implant, nanostructured titanium, histomorphometry

Abstract

Currently, titanium endosseous implants represent the standard in dental implantology. To improve their mechanical properties, biocompatibility and osseointegration, the concept of bulk nanostructured titanium with variously textured surface is being developed. Different animal species, mostly pigs, minipigs and rabbits, are used for the osseointegration assessment. The selection of implantation site in the target bone is also important, because various types of bones have different ratio between the compact and the trabecular bone tissue. After finishing the in vivo experiment, the implant position and orientation is verified by X-ray imaging. The part of the bone with the implant is surgically removed, cut into tissue blocks, and histologically processed using technique of undemineralized ground sections. This includes embedding the samples into resin followed by sawing, grinding, and polishing of transparent histological sections. A subsequent staining provides information on the formation and mineralization of the bone matrix in close proximity of the implant. Osseointegration is evaluated using a bone-implant contact (BIC) expressed as the ratio of the implant length in contact with bone tissue and total length of the implant. Additional information about the newly formed bone in regions surrounding the implant may be also provided by a double tetracycline test. According to our own experiments, this methodology is simple to perform, highly reproducible, and gives consistent results.

Published

2018-03-15

How to Cite

Moztarzadeh, A., Moztarzadeh, O., Kubíková, T., Tonar, Z., Hrušák, D., Zicha, A., & Babuška, V. (2018). Current Methods for Assessing Osseointegration of Nanostructured Titanium Implants. Chemické Listy, 112(3), 148–158. Retrieved from http://blog.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/3026

Issue

Section

Articles

Most read articles by the same author(s)